Gate Moves to End Stop, but Does not Complete Setup

Gate Moves to End Stop, but Does not Complete Setup

Possible causes: 

The origin magnet is missing or incorrectly mounted

Faulty origin sensor
Poor connection between battery and controller
The battery voltage is low or the battery is faulty or disconnected

 

Possible solutions: 

Check that the magnet is still mounted on the gate and that the gap between the magnet and the sensor is minimal. Refer to Figure 1 on page 2

Ensure that there is an audible ‘click’ whenever the magnet passes the origin sensor

Ensure that the arrow on the magnet is facing the operator – there should be a repelling action when the magnet is brought near the sensor

Ensure that the battery terminals are properly connected on both the controller and battery side

Measure the battery voltage – it should be no lower than 11V DC when placed under load. 

Check for corrosive build-up around the battery terminals; if there is corrosion replace both the battery and battery terminals.

Replace the battery

Measure the onboard charger’s output voltage. It should be about 14V DC with the battery disconnected



    • Related Articles

    • V-Series Electrical Setup and Configuration Guide

      Please find attached the installation manual for the V-Series, which includes the following sections: Required tools and equipment New site installation preparation Operator installation General description Icon used in this guide Electrical setup ...
    • Set Up Fail: No End Stops Found (D-Series)

      Possible Causes • Mechanical Endstops have not been installed • Oil in DOSS chamber • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End ...
    • Set Up Fail: No End Stops Found (D-Series)

      Possible Causes • Mechanical Endstops have not been installed • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End stops in order to ...
    • How to troubleshoot a Set Up Fail: Inconsistent End Stops error (D-Series)

      How to troubleshoot a Set Up Fail: Inconsistent End Stops error (D-Series) Possible Causes: · Mechanical end stops are not securely installed, allowing movement during operation. · Incorrect or poor meshing between the rack and pinion, such as: - ...
    • How to determine if there's an oil leak on the D5 Evo Sliding gate motor

      If you your gate is running a short distance and stop or slams into the ends stoppers, and your controller LCD screen is displaying either a ""gate stalled"", ""Motor fault"" or "" Max collision"" error, kindly refer to the below steps: Symptom: ...