Break In Alarm (V-Series)
Possible causes
• The
IR Beams have been interrupted with the gate in the fully closed position
•
Inadvertent activation of the Break-In Alarm feature
Solutions
•
Clear any obstruction from the path of the beams
• If
the lenses are unobstructed, check the wiring between the beams and the
controller, as well as between the IRB receiver and transmitter
•
Ensure that the beams are properly aligned
• If
not required, disable the Break-In Alarm feature in Menu 6: IR Beams
Related Articles
Break In Alarm (D-Series)
Possible causes: • The IR PE beams have been interrupted with the gate in the fully closed position • Inadvertent activation of the Break-in Alarm feature Solutions: • Clear any obstructions from the path of the PE beams • If the lenses are ...
Break In Alarm (D-Series)
Possible causes: • The IR PE beams have been interrupted with the gate in the fully closed position • Inadvertent activation of the Break-in Alarm feature Solutions: • Clear any obstructions from the path of the PE beams • If the lenses are ...
Break In Alarm (Sector)
Possible Causes • The closing loop has been activated while the boom is lowered • Inadvertent activation of the Break-in Alarm feature Solutions • Remove any metal objects from the closing loop • Check the loop wiring and impedance (should typically ...
Ambush Alarm ( V-Series)
Possible causes • The IR beams have been interrupted for the pre-set period of time with the Ambush Alarm feature enabled • Inadvertent activation of the Ambush Alarm feature Solutions • Clear any obstruction from the path of the beams • If the ...
V-Series Electrical Setup and Configuration Guide
Please find attached the installation manual for the V-Series, which includes the following sections: Required tools and equipment New site installation preparation Operator installation General description Icon used in this guide Electrical setup ...