30amp Motor fuse keep on blowing once powered up

30amp Motor fuse keep on blowing once powered up

 In our D-series range motors, the 30-amp fuse plays a critical role in protecting the motor from potential damage. However, there are certain factors that can cause this fuse to blow immediately. Understanding these factors is essential for ensuring the smooth operation of the system.

Possible causes:

  1. Voltage Fluctuations from Charger: One common cause of motor fuse blowing is when the outgoing voltage from the charger exceeds the recommended limits. Specifically, if the voltage surpasses 28V DC for standard systems (D10) or 14V DC for D5 EVO models, it can overload the motor circuit and trigger the fuse to blow. Monitoring and regulating the voltage output from the charger are crucial preventive measures.

  2. Short Circuits on Battery Wires: Another potential culprit behind blown motor fuses is a short circuit in the battery wiring. A short circuit occurs when there is an unintended connection between the positive and negative terminals of the battery, causing a surge of current that can overwhelm the fuse. Proper insulation and regular inspection of battery wires can help mitigate this risk.

  3. Faulty PC Board: A malfunctioning PC board within the system can also contribute to the blowing of the motor fuse. Issues such as component failure or circuitry damage can result in abnormal electrical behavior, leading to excessive current flow and fuse failure. Thorough diagnostics and timely repairs or replacements of faulty PC boards are essential for maintaining system integrity.

To prevent motor fuse blowing and ensure optimal performance:

  • Monitor Charger Output Voltage: Regularly check that the voltage output from the charger does not exceed 28V DC (D10) or 14V DC (D5 EVO), as specified for the system.
  • Verify Battery Polarity: Double-check that the battery wires are correctly wired, with the positive and negative terminals properly connected to prevent short circuits.
  • Inspect PC Board and Power Supply: If the above precautions are in order and the fuse continues to blow, it's crucial to bring in the PC board and power supply for thorough testing and diagnosis by qualified technicians at your closest CENTURION branch.
Kindly find the link below that carries al our branch details:



    • Related Articles

    • Fuse Blown or Drive Fault (D-Series)

      Possible causes • Intermittent or loose connection between motor and the 30A ATO motor fuse has been blown or removed • Faulty controller Solutions • The MOTOR, FUSE and DRIVE cells should all be ticked in the information screen • Check the ...
    • Fuse Blown or Drive Fault (D-Series)

      Possible causes • Intermittent or loose connection between motor and the 30A ATO motor fuse has been blown or removed • Faulty controller Solutions • The MOTOR, FUSE and DRIVE cells should all be ticked in the information screen • Check the ...
    • Drive Fault - Motor Drive Failure (D-Series)

      How to troubleshoot a drive fault failure on your D5 EVO, D10 or D10 Turbo Centurion Systems gate motor The error "Drive Fault - Motor Drive Failure" on your D5 EVO, D10 and D10 Turbo controller can be caused by: • Intermittent or loose connection ...
    • Drive Fault / Motor Drive Failure (Sector)

      Possible Causes • Loose drive connections • Faulty electric motor • The H-bridge on the controller is damaged, possibly a blown FET • The electric motor is faulty or has been disconnected Solutions • Check drive connections (motor and battery) and ...
    • Drive Fault - Motor Drive Failure (D-Series)

      Possible causes: • Intermittent or loose connection between motor and controller • The H-bridge on the controller is damaged, possibly a blown FET • The electric motor is faulty or has been disconnected Solutions: • Check drive connections • Check ...