Fuse Blown or Drive Fault (D-Series)

Fuse Blown or Drive Fault (D-Series)

Possible causes
• Intermittent or loose connection between motor and the 30A ATO motor fuse has been blown or removed
• Faulty controller

Solutions
• The MOTOR, FUSE and DRIVE cells should all be ticked in the information screen
• Check the continuity of the fuse with a multi-meter – set the meter to ‘ohms’ or audio output
• If the fuse keeps blowing if replaced, the controller is faulty and must be replaced
    • Related Articles

    • How to Troubleshoot a Motor or Drive Fault Failure on the D-Series Sliding Gate Motor

      If you encounter the “Drive Fault - Motor Drive Failure” error on your D5 EVO, D10, or D10 Turbo controller, the issue may be caused by: Loose or intermittent connections between the motor and controller A damaged H-bridge on the controller, such as ...
    • How to Troubleshoot a Motor or Drive Fault Failure on the D-Series Sliding Gate Motor

      If you encounter the “Drive Fault - Motor Drive Failure” error on your D5 EVO, D10, or D10 Turbo controller, the issue may be caused by: Loose or intermittent connections between the motor and controller A damaged H-bridge on the controller, such as ...
    • Fuse Blown or Drive Fault (D-Series)

      Possible causes • Intermittent or loose connection between motor and the 30A ATO motor fuse has been blown or removed • Faulty controller Solutions • The MOTOR, FUSE and DRIVE cells should all be ticked in the information screen • Check the ...
    • Drive Fault / Motor Drive Failure (Sector)

      Possible Causes • Loose drive connections • Faulty electric motor • The H-bridge on the controller is damaged, possibly a blown FET • The electric motor is faulty or has been disconnected Solutions • Check drive connections (motor and battery) and ...
    • 30amp Motor fuse keep on blowing once powered up

      In our D-series range motors, the 30-amp fuse plays a critical role in protecting the motor from potential damage. However, there are certain factors that can cause this fuse to blow immediately. Understanding these factors is essential for ensuring ...