If you need to convert your right hand operator boom to a left hand operator boom to meet your site requirements, please follow the steps below: Remove Counterbalance Assembly: Remove the Boom Pole. With the Door and Electronics Assembly removed, ...
Wiring: Programming: 1. Under Chrono-guard menu select Auto XIO 2. Select start time and end time (Ex. Start: MTWTF 07:00, End: MTWTF 17:00) 3. Invert logic OFF 4. Remote learned in as a Latch on the receiver. Basic Operation: When XIO is active ...
If you encounter the “Drive Fault - Motor Drive Failure” error on your D5 EVO, D10, or D10 Turbo controller, the issue may be caused by: Loose or intermittent connections between the motor and controller A damaged H-bridge on the controller, such as ...
Please find attached the installation manual for the D20 SMART, which includes the following sections: Introduction Specifications Product identification Required tools and equipment New site installation preparation Lubrication Operator installation ...
The DOSS is an opto-electronic system that counts pulses to determine the gate’s position and the distance required to reach its respective endstops. Possible Causes of Error: DOSS physically disconnected Poor connection on the DOSS or controller ...