Waiting for Co-Processor (Sector)

Waiting for Co-Processor (Sector)

Possible Causes
• Poor connection between battery and controller
• The battery voltage is low or the battery is faulty or
disconnected
• Faulty controller

Solutions
• Ensure that the battery terminals are properly connected
• Measure the battery voltage – it should be no lower than
11V DC when placed under load. 
• Check for corrosive build-up around the battery terminals.
If there is corrosion, replace both the battery and
terminals
• Replace the battery
• Ensure that the ‘Mains Present’ icon is solid
• Replace faulty controller

    • Related Articles

    • Waiting for Co-Processor / Wait 1 minute or Reset All Power (D-Series)

      Possible causes: • Poor connection between battery and controller • The battery voltage is low • The battery is faulty or disconnected • Faulty controller Solutions: • Ensure that the battery terminals are properly connected on both the controller ...
    • Waiting for Co-Processor / Wait 1 minute or Reset All Power (D-Series)

      Possible causes: • Poor connection between battery and controller • The battery voltage is low • The battery is faulty or disconnected • Faulty controller Solutions: • Ensure that the battery terminals are properly connected on both the controller ...
    • Waiting for Co-processor – Wait 1 minute or reset ALL power

      Possible causes • Poor connection between battery and controller • The battery voltage is low or the battery is faulty or disconnected • Faulty controller   Solutions • Ensure that the battery terminals are properly connected • Measure the battery ...
    • How do I override Auto FRX on Sector Controllers

      Wiring: Programming: 1. Under Chrono-guard menu select Auto XIO 2. Select start time and end time (Ex. Start: MTWTF 07:00, End: MTWTF 17:00) 3. Invert logic OFF 4. Remote learned in as a Latch on the receiver. Basic Operation: When XIO is active ...
    • Sector 2 Installation Manual

      Please find attached the installation manual for the Sector 2 boom barrier, which includes the following sections: Glossary of terms Product identification Physical installation Onsite electrical wiring Basic controller setup Installation handover ...