Set Up Fail No Endstops Found (Sector)

Set Up Fail No Endstops Found (Sector)

Possible Causes
• DOSS is faulty or disconnected
• The gearbox is slipping

Solutions
• Replace faulty DOSS or reconnect the unplugged connections
• Contact an authorised agent to service the gearbox
• Tighten the drive-arm or contact an authorised agent
    • Related Articles

    • Set Up Fail: No End Stops Found (D-Series)

      Possible Causes • Mechanical Endstops have not been installed • Oil in DOSS chamber • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End ...
    • No Limits Set (Sector)

      This error will display if the End-of-travel limits have not been established. Solution • Set the gate travel limits by accessing the Setting Limits menu (Menu1: Setting Limits) and following the onscreen prompts or steps supplied below: The ...
    • Set Up Fail: Inconsistent End Stops (Sector)

      Possible Cause • One or both Endstops are moving • The gearbox is slipping Solution • Use a Phillips screwdriver to sufficiently tighten the open and closed Endstops. They should not move at all when subjected to force • Tighten the drive-arm or ...
    • How do I override Auto FRX on Sector Controllers

      Wiring: Programming: 1. Under Chrono-guard menu select Auto XIO 2. Select start time and end time (Ex. Start: MTWTF 07:00, End: MTWTF 17:00) 3. Invert logic OFF 4. Remote learned in as a Latch on the receiver. Basic Operation: When XIO is active ...