Set Up Fail: Inconsistent End Stops (Sector)

Set Up Fail: Inconsistent End Stops (Sector)

Possible Cause
• One or both Endstops are moving
• The gearbox is slipping

Solution
• Use a Phillips screwdriver to sufficiently tighten the open
and closed Endstops. They should not move at all when
subjected to force
• Tighten the drive-arm or contact an authorised agent


    • Related Articles

    • Set Up Fail: No End Stops Found (D-Series)

      Possible Causes • Mechanical Endstops have not been installed • Oil in DOSS chamber • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End ...
    • Set Up Fail: Inconsistent End Stops (D-Series)

      Possible Causes • Mechanical Endstops are not securely fitted • Poor meshing between rack and pinion due to excessive gap, missing teeth, etc. • Faulty DOSS sensor • Electric fence contact preventing gate from reaching fully closed position Solutions ...
    • Set Up Fail: Inconsistent End Stops (D-Series)

      Possible Causes • Mechanical Endstops are not securely fitted • Poor meshing between rack and pinion due to excessive gap, missing teeth, etc. • Faulty DOSS sensor • Electric fence contact preventing gate from reaching fully closed position Solutions ...
    • Set Up Fail: No End Stops Found (D-Series)

      Possible Causes • Mechanical Endstops have not been installed • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End stops in order to ...
    • No Limits Set (Sector)

      This error will display if the End-of-travel limits have not been established. Solution • Set the gate travel limits by accessing the Setting Limits menu (Menu1: Setting Limits) and following the onscreen prompts or steps supplied below: The ...