Resolving

Resolving

Possible causes

• The gate is encountering an obstruction

• Excessive wind loading

• Actuator not fully engaged

• Sensor cables may not be connected, incorrectly

connected, crimped or cut

• Gate leaf may be too long

• Short Ramp-up and Ramp-down distances

• Gate leaves have fallen out of synchronisation

• Dimensions for A, B, and C are incorrect

 

Solutions

• Ensure that nothing is physically hindering the trajectory of the gate

• Ensure that installation dimensions of the actuator’s rear mounting bracket are according to specification

• Engage actuator by turning the key fully clockwise

• Check all sensor wire connections and joints

• Ensure that the length of the gate leaf is within specification

• Increase the Ramp-up and Ramp-down distances (Menu 5: Run Profile)

• Reset Gate Limits