Presence Alarm (Sector)

Presence Alarm (Sector)

Possible Causes
• The closing loop has been activated for the time specified
in Menu 6.5.1.2: Presence Time
• Inadvertent activation of the Presence Alarm feature

Solutions
• Remove any metal objects from the closing loop
• Check the loop wiring and impedance (should typically be
<5Ω)
• If not required, disable the Presence Alarm feature in
Menu 6: Loop Detector

    • Related Articles

    • Break In Alarm (Sector)

      Possible Causes • The closing loop has been activated while the boom is lowered • Inadvertent activation of the Break-in Alarm feature Solutions • Remove any metal objects from the closing loop • Check the loop wiring and impedance (should typically ...
    • Sector 2 Installation Manual

      Please find attached the installation manual for the Sector 2 boom barrier, which includes the following sections: Glossary of terms Product identification Physical installation Onsite electrical wiring Basic controller setup Installation handover ...
    • How do I override Auto FRX on Sector Controllers

      Wiring: Programming: 1. Under Chrono-guard menu select Auto XIO 2. Select start time and end time (Ex. Start: MTWTF 07:00, End: MTWTF 17:00) 3. Invert logic OFF 4. Remote learned in as a Latch on the receiver. Basic Operation: When XIO is active ...
    • Ambush Alarm (D-Series)

      Possible causes: • The IR PE beams have been interrupted for the pre-set period of time with the Ambush Alarm feature enabled • Inadvertent activation of the Ambush Alarm feature Solutions: • Clear any obstruction from the path of the PE beams • If ...
    • Ambush Alarm (D-Series)

      Possible causes: • The IR PE beams have been interrupted for the pre-set period of time with the Ambush Alarm feature enabled • Inadvertent activation of the Ambush Alarm feature Solutions: • Clear any obstruction from the path of the PE beams • If ...