How to wire your tamper alarm on your Smart motor to a G-ultra device to send notifications when tamper is active.

How to wire your tamper alarm on your Smart motor to a G-ultra device to send notifications when tamper is active.

 First, connect your wires to the designated unused IO on the G-Ultra and the unused IO on the Smart motor:



 After completing the wiring, proceed with the following settings on gweb:

1. Navigate to IO settings, select the IO you have wired, and configure it as an input. You can also name the input for clarity.
 
2. Move to the Access profile section, find the notification settings for the required profile, and create your global string.
 
3. Assign the notification you've created in the global string to the designated input under the inputs trigger output notification, specifically for the falling input event and tick the channel you would like to receive the notification: 
 

For settings on the Smart motor:

1. Open the MyCentsys Pro app and connect to your motor.
 2. Click on the cycle icon with three dots in the middle, located at the bottom of the page.

3. Tap on 'settings'.
 

4. From the drop-down menu, select 'alarms'.
 
5. Tap and select 'theft alarm'

6. Enable the theft alarm using the toggle switch.
 
7. Assign the IO used on the gate motor as your alarm input.