How to setup the limits on the SDO4 garage operator.

How to setup the limits on the SDO4 garage operator.

Frist step: Select the door type.

Once the mains and batteries are connected the LCD display will alternate between LL and SE. By default the SDO4 is set as SE - for sectional doors. If this is the type of door being automated press the confirm button once only L.L will now be shown on the LCD display. Should a Tip-Up door be used single press of the “+” or “-“ button will change this to Tu - Tip-Up door. The display will now alternate between LL and Tu, press confirm and only L.L will be displayed.

Second step: Start automatic setup.

Once the door type has been confirmed press the Confirm button once. The door will start by closing first, once the closed end stop has been reached the door will move to the open position, once the open end stop has been confirmed the door will move to the closed position and stop. A single “.” Dot will be displayed to indicate a successful setup and the SDO4 is now in standby mode.

Optional:

Modifying the position of the door. The limits must be started from approximately the midway position. Should the door be within approximately 200mm of the closed position or open position, use the “+” button (open) or “-“ (close) by pressing and holding it down to drive the door to the midway position then start the limit setup. (this can only be done after door type has been selected)
    • Related Articles

    • How to Power Up the RDO Digital Garage Operator for the First Time and How to Setup the Operator

      Kindly find the steps on how to power up the RDO Digital for the first time and setting up the operator limits detailed below: Kindly find the video tutorial with steps blow: Powering Up: When the PCB (Controller) is powered on for the first time, ...
    • CENTURION RDO-Digital - Garage Door Operator Manaul

      Please find attached the installation manual for the RDO-Digital installation manual, which includes the following sections: Important safety instructions Specifications Product identification New site installation preparation Operator installation ...
    • No Limits Set (D-Series)

      Possible cause: • The End-of-Travel limits have not been established Solution: • Set the gate travel limits by accessing the Setting Limits menu (Menu 1: Setting Limits) and following the onscreen prompts (Steps attached)
    • No Limits Set (D-Series)

      Possible cause: • The End-of-Travel limits have not been established Solution: • Set the gate travel limits by accessing the Setting Limits menu (Menu 1: Setting Limits) and following the onscreen prompts (Steps attached) 
    • V-Series Electrical Setup and Configuration Guide

      Please find attached the installation manual for the V-Series, which includes the following sections: Required tools and equipment New site installation preparation Operator installation General description Icon used in this guide Electrical setup ...