How to Set Up Limits on a V-Series (VX) SMART Swing Gate Motor

How to Set Up Limits on a V-Series (VX) SMART Swing Gate Motor

To set up or reset the limits on your V-Series SMART Swing Gates, please follow the steps below:
Limits steps carried in the video below:

Follow the steps below to set or reset the limits on your V-Series SMART Swing Gate:

  1. Download the MyCentsys Pro App
    If you haven't yet installed the app on your smartphone, download it from your app store.

  2. Connect to the Motor
    Open the app and connect to your motor. For new installations, tap on the Set Gate Limits option. If resetting limits, tap on the Configure Cycle, select Settings, and tap on Setup Wizard.

  3. Enter Operator Details
    On the operator location details page, input your preferred operator name, select your region, and choose the correct time zone. Once done, tap Next.

  4. Gate Lock Selection
    Select whether a gate lock is present, then tap Next.

  5. Single or Double Swing Gate
    Choose whether your setup includes a single swing gate or a double swing gate by tapping the corresponding image.

  6. Leaf Delay
    If your gate has a lock or lip, select Yes for a leaf delay or No if not required

  7. Safety Device Notification
    You will be notified that safety devices like beams won't function during the limits setup. Tap Confirm to proceed.

  8. Safety Checks
    Confirm that the origin clamps are installed, then tap Confirm.

  9. Gate Swing Direction
    Select whether your gate swings Inward or Outward, then tap Next.

  10. Motor Engagement
    If the motor is not engaged, lock the arm with the provided key and tap Next.

  11. Clear the Area & Start
    Ensure the gate area is clear and tap Start to begin the limits setup.

  12. Master Gate Direction
    The master gate leaf will open slightly. Confirm the direction is correct by selecting Yes if applicable.

  13. Slave Gate Direction
    The slave gate will also open slightly. Confirm the direction is correct by selecting Yes. Both gates will then fully open and close to automatically adjust the speed and current based on your setup.

  14. Final Confirmation
    The system will generate a report showing the maximum speed, peak currents, and sensitivities. Once the settings have been validated and saved, your motor is ready for operation.


    • Related Articles

    • No Limits Set (V-Series)

      Possible Cause • The End-of-travel limits have not been established Solution • Set the Gate Travel Limits by accessing the Setting Limits Menu (Menu 1: Setting Limits) and following the onscreen prompts
    • VX Controller vs. V-Series Controller

      The advantages of using a VX controller over a V-Series controller: 1. Programming Flexibility: Settings on the VX controller can be easily programmed using a dedicated app, offering convenience and ease of customization. 2. External Gate Status ...
    • VX Controller vs. V-Series Controller

      The advantages of using a VX controller over a V-Series controller: 1. Programming Flexibility: Settings on the VX controller can be easily programmed using a dedicated app, offering convenience and ease of customization. 2. External Gate Status ...
    • VX Controller vs. V-Series Controller

      The advantages of using a VX controller over a V-Series controller: 1. Programming Flexibility: Settings on the VX controller can be easily programmed using a dedicated app, offering convenience and ease of customization. 2. External Gate Status ...
    • VX Controller vs. V-Series Controller

      The advantages of using a VX controller over a V-Series controller: 1. Programming Flexibility: Settings on the VX controller can be easily programmed using a dedicated app, offering convenience and ease of customization. 2. External Gate Status ...