Limit Setup for a SMART Sliding Gate Operator

Limit Setup for a SMART Sliding Gate Operator

Quote

Performing a Limit Setup on a SMART Sliding Gate Operator

  • Explains the process of setting the open and closed limits on a SMART sliding gate operator to ensure accurate and reliable gate operation.
Notes

Summary

Provides the steps required to perform a limit setup on a SMART sliding gate operator. A limit setup is required during the initial installation, after a factory reset, or whenever the gate travel or operator position has been adjusted.


Info

Before You Begin

Before starting the limit setup, ensure the following:

  • The operator is engaged.
  • There are no obstructions in the gate's path.
  • The gate can move freely through its full travel.

Step-by-Step Guide

Step 1: Connect to the Operator

  1. Open the MyCentsys Pro app.
  2. Connect to the gate operator.

Step 2: Open the Setup Wizard

  1. Tap the three dots at the bottom centre of the screen.
  2. Select Settings.
  3. Tap Setup Wizard.

Step 3: Set the Operator Name (Optional)

  1. You will have the option to change the operator name.
  2. Edit the name if required.
  3. Tap Next.

Step 4: Set the Maximum Speed

  1. Select the maximum speed at which the operator should run.
  2. Tap Next.

Step 5: Review the Safety Warnings

  1. Carefully read through the warnings displayed on the screen.
  2. Once you have read them, tap Start.

Step 6: Learn the Gate Limits

  1. The gate will begin moving at a slow speed.
  2. Once it reaches the first end stop, confirm that it has reached the end stop.
  3. The operator will then move the gate towards the opposite end stop.
  4. Confirm when the gate has reached the second end stop.

Step 7: Automatic Verification

  1. The operator will automatically perform two additional full-speed cycles.
  2. These cycles verify that the gate limits have been learned correctly.

Step 8: Select the Gate Position

  1. Once the limit setup is complete, select whether the gate is currently:
    • Open, or
    • Closed.

Step 9: Gate Report

  1. A Gate Report will be displayed.
  2. Review the information if required.
  3. Tap Done to continue.

Step 10: Configuration Wizard

  1. You will be prompted to run the Configuration Wizard.
  2. If no additional configuration is required, select No to skip this step.

Result

The limit setup is now complete, and the operator has successfully learned the fully open and fully closed positions of the gate. The gate is now ready for normal operation.

Notes

Should you need further assistance or more information, please do not hesitate to reach out to our support gurus via our Centurion Systems WhatsApp service (+27836504010).