Gate Runs a Short Distance and Stops
Possible
causes:
Battery low condition
Multiple collision condition
Collision sensing too sensitive
Faulty motor assembly
Faulty controller
Faulty or disconnected DOSS
Possible
solutions:
Measure battery voltage under static and load
conditions as per the procedure described later. Replace if necessary
Ensure that duty cycle is not exceeded (10
operations per day)
Clean any corrosive build-up around the battery
terminals
Check for something physically obstructing the
movement of the gate or set the sensitivity from High to Medium or Low
nsure that the DOSS is plugged in on the controller and encoder side.
Bring in the motor for testing at your closest
CENTURION branch as the motor assembly, controller or DOSS might be faulty
Related Articles
Gate Runs a Short Distance and Stops - (Status flashing 4 times)
Possible causes: Multiple collision condition Incorrect or loose wiring Loose fuse Sensor unplugged or faulty Possible solutions: Adjust collision sensitivity (high to medium or to low) Check for something physically obstructing the movement of ...
Set Up Fail: No End Stops Found (D-Series)
Possible Causes • Mechanical Endstops have not been installed • Oil in DOSS chamber • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End ...
Gate Runs a Short Distance and Stops (Status flashing 3 times)
Possible causes: Battery low condition (Status flashing 3 times) Old battery Possible solutions: Check battery charger Check that the charge voltage is 13.7V with no battery connected Charge rate (Check recovery rate of charger) Check duty cycle of ...
How to determine if there's an oil leak on the D5 Evo Sliding gate motor
If you your gate is running a short distance and stop or slams into the ends stoppers, and your controller LCD screen is displaying either a ""gate stalled"", ""Motor fault"" or "" Max collision"" error, kindly refer to the below steps: Symptom: ...
Set Up Fail: No End Stops Found (D-Series)
Possible Causes • Mechanical Endstops have not been installed • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End stops in order to ...