Gate Runs a Short Distance and Stops (Status flashing 3 times)
Possible
causes:
Battery low condition (Status flashing 3 times)
Old battery
Possible
solutions:
Check battery charger
Check that the charge voltage is 13.7V with no battery connected
Charge rate (Check recovery rate of charger)
Check duty cycle of system (battery capacity sufficient)
Check condition of battery leads and connectors
Related Articles
Gate Runs a Short Distance and Stops - (Status flashing 4 times)
Possible causes: Multiple collision condition Incorrect or loose wiring Loose fuse Sensor unplugged or faulty Possible solutions: Adjust collision sensitivity (high to medium or to low) Check for something physically obstructing the movement of ...
Gate Runs a Short Distance and Stops
Possible causes: Battery low condition Multiple collision condition Collision sensing too sensitive Faulty motor assembly Faulty controller Faulty or disconnected DOSS Possible solutions: Measure battery voltage under static and load conditions as ...
Set Up Fail: No End Stops Found (D-Series)
Possible Causes • Mechanical Endstops have not been installed • Oil in DOSS chamber • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End ...
How to troubleshoot a Low Battery Voltage Condition (STATUS light flashes 3 times) on the CP80 D3 or D5
If you find yourself unable to close or open your gate or the gate stops short, and your controller status LED flashes 3 times with a pause, kindly refer to the below possible causes for this error to appear: Symptom: -When you press your remote or ...
R3 & R5 Installation Manual
Please find attached the installation manual for the R3 & R5 swing gate motors, which includes the following sections: Safety instructions Mechanical setup Electric setup General Description Specifications Product identification Required tools and ...