Gate Does not Open From the Fully Closed Position (one beep every two seconds)
Possible
causes:
Closing infrared gate safety beams interrupted
Closing infrared safety beams faulty, misaligned or disconnected
Damaged Safe Common input
Possible
solutions:
Ensure that no people or objects are in the path of the beam
Ensure that the Safety Open and Safety Close LEDs are lit – if not, the
inputs can be permanently bridged to Com, or the controller can be reset to
factory defaults.
Bridging the safety inputs will disable all safety features and poses a
safety hazard!
Ensure that the beams are in working order
Related Articles
Gate Does not Open From the Fully Closed Position (one beep every two seconds)
Possible causes: Opening infrared gate safety beams interrupted Opening infrared safety beams faulty, misaligned or disconnected Damaged Safe Common input Possible solutions: Ensure that no people or objects are in the path of the beam Ensure ...
D5 Evo/D10/D10 Turbo Configuration Guide
Please find attached the installation manual for the D5 Evo/D10/D10 Turbo, which includes the following sections: Commissioning the system Setting up additional features Menu navigation map Diagnostic LED's Buzzer feedback Electrical setup ...
Gate Does not Open From the Fully Closed Position (three short beeps)
Possible causes: Opening infrared gate safety beams incorrectly wired Opening beams faulty Possible solutions: Ensure that the beam receiver relay Com has been connected to Safe Com (Centurion photon beams only) Replace faulty infrared PE beams
D2 Turbo User Guide
Please find attached the Mechanical User Guide for the D2 Turbo, which includes the following sections: Identification of parts manual override Features and functions Customizing the features and functions Additional features Basic maintenance ...
V-Series Electrical Setup and Configuration Guide
Please find attached the installation manual for the V-Series, which includes the following sections: Required tools and equipment New site installation preparation Operator installation General description Icon used in this guide Electrical setup ...