    • Set Up Fail: No End Stops Found (D-Series)

      Possible Causes • Mechanical Endstops have not been installed • Oil in DOSS chamber • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End ...
    • Set Up Fail: No End Stops Found (D-Series)

      Possible Causes • Mechanical Endstops have not been installed • DOSS faulty or disconnected • Electric fence contact preventing gate from reaching fully closed position • Faulty electrical motor Solutions • Install physical End stops in order to ...
    • Set Up Fail: Inconsistent End Stops (Sector)

      Possible Cause • One or both Endstops are moving • The gearbox is slipping Solution • Use a Phillips screwdriver to sufficiently tighten the open and closed Endstops. They should not move at all when subjected to force • Tighten the drive-arm or ...
    • Gate Moves to End Stop, but Does not Complete Setup

      Possible causes:  The origin magnet is missing or incorrectly mounted Faulty origin sensor Poor connection between battery and controller The battery voltage is low or the battery is faulty or disconnected   Possible solutions:  Check that the magnet ...
    • Set Up Fail: Inconsistent End Stops (D-Series)

      Possible Causes • Mechanical Endstops are not securely fitted • Poor meshing between rack and pinion due to excessive gap, missing teeth, etc. • Faulty DOSS sensor • Electric fence contact preventing gate from reaching fully closed position Solutions ...